Disposable Medical Latex Foley Catheter (2 way, 3way)

Product Details
Customization: Available
Type: Surgical Supplies Materials
Material: Plastic
Manufacturer/Factory, Group Corporation
Gold Member Since 2008

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (12)
  • Disposable Medical Latex Foley Catheter (2 way, 3way)
  • Disposable Medical Latex Foley Catheter (2 way, 3way)
  • Disposable Medical Latex Foley Catheter (2 way, 3way)
  • Disposable Medical Latex Foley Catheter (2 way, 3way)
Find Similar Products

Basic Info.

Model NO.
QDMH 005
1-3 Ways
Fr8-Fr26
Transport Package
500PCS/CTN
Specification
CE/ISO
Trademark
OEM/MEDIADO
Origin
China
HS Code
90183900
Production Capacity
100000PCS/Month

Product Description

Product Name: Disposable Medical Latex Foley Catheter (2 way, 3way)
2,3-WAY FOLEY CATHETERS 
 1.SIZE: 16-26Fr/5,10,15,30,50ml
2.USE: Indwelling or urethral catheterization,bladder drip.
 
DIRECTIONS:
1.LUBRICATION: lubricate the latex urethral catheter with medical lubricants before use. Wet the superlubricous catheter with sterile water before use and superlubricous can be achieved without any lubricants.
2.INSERTION: Carefully insert the lubricated catheter into the bladder(normally indicated by urine flow),then a further 3cm
3.WATER FILLING: Hold the valve bush, insert the syringe without needle into the valve and introduce rate4d amount of sterile water.After that, pull softly the catheter outward until bladder is chocked by the inflated balloon.
4.TAKING OUT:When taking out the catheter from the bladder,insert an empty syringe into the valve and let the water flow out naturally,or cut off the shaft for quick drainage of water.
5.RETENTION TIME: The retention time is determined in accordance with 
the clinical and nursing requirements

2-WAY FOLEY CATHETERS
 DESCRIPTION:
1.SIZE: 12-26Fr/5,10,15,30,50ml
2.USE: Indwelling or hemostasia urethral catheterization. 
DIRECTIONS:
1.LUBRICATION: lubricate the latex urethral catheter with medical lubricants before use. Wet the superlubricous catheter with sterile water before use and superlubricous can be achieved without any lubricants.
2.INSERTION: Carefully insert the lubricated catheter into the bladder(normally indicated by urine flow),then a further 3cm
3.WATER FILLING: Hold the valve bush, insert the syringe without needle into the valve and introduce rate4d amount of sterile water.After that, pull softly the catheter outward until bladder is chocked by the inflated balloon.
4.TAKING OUT:When taking out the catheter from the bladder,insert an empty syringe into the valve and let the water flow out naturally,or cut off the shaft for quick drainage of water.
5.RETENTION TIME: The retention time is determined in accordance with 
the clinical and nursing requirements.

2-WAY FOLEY CATHETERS FOR CHILDREN 
 
DESCRIPTION:
1.SIZE: 6-10Fr/3ml,5ml
2.USE: Indwelling or urethral catheterization for children.
 
DIRECTIONS:
1.LUBRICATION: lubricate the latex urethral catheter with medical lubricants before use. Wet the superlubricous catheter with sterile water before use and superlubricous can be achieved without any lubricants.
2.INSERTION: Carefully insert the lubricated catheter into the bladder(normally indicated by urine flow),then a further 3cm
3.WATER FILLING: Hold the valve bush, insert the syringe without needle into the valve and introduce rate4d amount of sterile water.After that, pull softly the catheter outward until bladder is chocked by the inflated balloon.
4.TAKING OUT:When taking out the catheter from the bladder,insert an empty syringe into the valve and let the water flow out naturally,or cut off the shaft for quick drainage of water.
5.RETENTION TIME: The retention time is determined in accordance with 
the clinical and nursing requirements
 
NELATON CATHETERS
 
DESCRIPTION:
1.SIZE: 6-22Fr
 
2.USE: Provisional urethral catheterization.
DIRECTIONS:
1.LUBRICATION: lubricate the latex urethral catheter with medical lubricants before use. Wet the superlubricous catheter with sterile water before use and superlubricous can be achieved without any lubricants.
2.INSERTION: Carefully insert the lubricated catheter into the bladder(normally indicated by urine flow),then a further 3cm
3.WATER FILLING: Hold the valve bush, insert the syringe without needle into the valve and introduce rate4d amount of sterile water.After that, pull softly the catheter outward until bladder is chocked by the inflated balloon.
4.TAKING OUT:When taking out the catheter from the bladder,insert an empty syringe into the valve and let the water flow out naturally,or cut off the shaft for quick drainage of water.
5.RETENTION TIME: The retention time is same as 2 way and 3 way foley catheters.









 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier